Number of Cylinders |
N/A 4 |
Displacement I Stage at 50 Hz |
N/A 949.05 ft³/h |
Displacement II Stage at 50 Hz |
N/A 675.67 ft³/h |
Displacement I Stage at 60 Hz |
N/A 1,138.72 ft³/h |
Displacement II Stage at 60 Hz |
N/A 810.95 ft³/h |
Motor Power |
N/A 7.5 hp5.5 kW |
Part Winding Start (PWS) Motor Voltage at 50 Hz |
N/A 380 to 420 V |
Motor Phase at 50 Hz |
N/A 3 |
Part Winding Start (PWS) Motor Voltage at 60 Hz |
N/A 440 to 480 V |
Motor Phase at 60 Hz |
N/A 3 |
Part Winding Start (PWS) Motor Partition |
N/A 50-50 |
Direct On Line (DOL) Bridge Bars |
N/A Standard |
Maximum Running Amperage (MRA) Maximum Operating Current at 400 V/50 Hz and 460 V/60 Hz |
N/A 18 A |
Locked Rotor Amperage (LRA) Maximum Starting Current at 400 V/50 Hz and 460 V/60 Hz, Part Winding Start (PWS) Motor |
N/A 47 A |
Locked Rotor Amperage (LRA) Maximum Starting Current at 400 V/50 Hz and 460 V/60 Hz, Part Winding Start (PWS) Motor with Direct On Line (DOL) Connection |
N/A 75 A |
Maximum Power Consumption at 50 Hz |
N/A 8.7 kW |
Minimum Frequency |
N/A 50 Hz |
Maximum Frequency |
N/A 60 Hz |
Protection Device |
N/A INT69® Diagnose |
Enclosure Class |
N/A IP56 |
High Pressure (HP) |
N/A 435.0 psi |
Low Pressure (LP) |
N/A 297.3 psi |
Oil Type |
N/A POE32 |
Oil Charge (3/4 of Sight Glass) |
N/A 98.06 fl oz |
Lubrication Type |
N/A Centrifugal |
Suction Valve Size |
N/A 1 3/8 in |
Discharge Valve Size |
N/A 7/8 in |
Net Weight |
N/A 268.96 lb |
Number of Stages |
N/A 2 |
Series |
N/A S |
Applications |
N/A
|