Items |
/Asset/Frascold-Q-VS-Series-Compressors-with-Integrated-Inverter.jpg Q5-21Yvs 11.6 Ampere (A) Maximum Operation Current Frascold Q5 VS Series Compressor with Integrated Inverter |
/Asset/Frascold-Q-VS-Series-Compressors-with-Integrated-Inverter.jpg Q5-24Yvs 13.8 Ampere (A) Maximum Operation Current Frascold Q5 VS Series Compressor with Integrated Inverter |
/Asset/Frascold-Q-VS-Series-Compressors-with-Integrated-Inverter.jpg Q7-28Yvs 17.6 Ampere (A) Maximum Operation Current Frascold Q7 VS Series Compressor with Integrated Inverter |
/Asset/Frascold-Q-VS-Series-Compressors-with-Integrated-Inverter.jpg Q7-33Yvs 20 Ampere (A) Maximum Operation Current Frascold Q7 VS Series Compressor with Integrated Inverter |
||||
Description | N/A 9 compressor models 4 cylinders, with displacement from 4.20 [30 Hz] to 57.30 [87 Hz] and nominal power from 1.5 to 7.5 hp. The inverter is mounted on the compressor and is pre-programmed to be managed by an external OID controller or a pressure transducer that can be mounted on the suction line. The calibration of all the parameters that control the inverter can be customized according to the specific application. | |||||||
Number of Cylinders | N/A 4 | |||||||
Displacement at 50 Hz | N/A 675.67 ft³/h | N/A 844.50 ft³/h | N/A 989.67 ft³/h | N/A 1,153.55 ft³/h | ||||
Displacement at 60 Hz | N/A 810.81 ft³/h | N/A 1,013.40 ft³/h | N/A 1,187.60 ft³/h | N/A 1,384.26 ft³/h | ||||
Motor Version | N/A 1 | |||||||
Motor Power | N/A 5 hp3.7 kW | N/A 5 hp3.7 kW | N/A 7.5 hp5.5 kW | N/A 7.5 hp5.5 kW | ||||
Motor Voltage at 50 Hz | N/A 400 V | |||||||
Motor Voltage at 60 Hz | N/A 400 V | |||||||
Motor Phase at 50 Hz | N/A 3 | |||||||
Motor Phase at 60 Hz | N/A 3 | |||||||
Direct On Line (DOL) Bridge Bars | N/A Standard | |||||||
Maximum Running Amperage (MRA) Maximum Operating Current at 400 V/50 Hz and 460 V/60 Hz | N/A 11.6 A | N/A 13.8 A | N/A 17.6 A | N/A 20 A | ||||
Locked Rotor Amperage (LRA) Maximum Starting Current at 400 V/50 Hz and 460 V/60 Hz, Part Winding Start (PWS) Motor with Direct On Line (DOL) Connection | N/A 63.1 A | N/A 63.1 A | N/A 87.3 A | N/A 87.3 A | ||||
Maximum Power Consumption at 50 Hz | N/A 6.6 kW | N/A 7.9 kW | N/A 9.5 kW | N/A 11.2 kW | ||||
Minimum Frequency | N/A 25 Hz | |||||||
Maximum Frequency | N/A 87 Hz | |||||||
Protection Device | N/A No | |||||||
Enclosure Class | N/A IP56 | |||||||
High Pressure (HP) | N/A 435.0 psi | |||||||
Low Pressure (LP) | N/A 297.3 psi | |||||||
Oil Type | N/A POE32 | |||||||
Oil Charge (3/4 of Sight Glass) | N/A 54.10 fl oz1.6 L | N/A 54.10 fl oz | N/A 54.10 fl oz | N/A 54.10 fl oz | ||||
Lubrication Type | N/A Centrifugal | |||||||
Suction Valve Size | N/A 1 1/8 in | N/A 1 1/8 in | N/A 1 3/8 in | N/A 1 3/8 in | ||||
Discharge Valve Size | N/A 3/4 in | N/A 7/8 in | N/A 1 1/8 in | N/A 1 1/8 in | ||||
Net Weight | N/A 184.53 lb83.7 kg | N/A 195.55 lb | N/A 195.55 lb | N/A 195.55 lb | ||||
Series | N/A Q5 | N/A Q5 | N/A Q7 | N/A Q7 | ||||
Advantages |
N/A
The advantages of VS compressors are:
|
|||||||
|